Просмотр исходного кода

fix: IoTDB name for version option

The previous name for the version option was v1.0.x which is clearly
wrong since this option was tested against IoTDB version v1.1.0. This
commit fixes this by renaming the option to v1.x.

Fixes:
https://emqx.atlassian.net/browse/EMQX-9926
Kjell Winblad 2 лет назад
Родитель
Сommit
89ea1646be

+ 1 - 1
apps/emqx_bridge_iotdb/include/emqx_bridge_iotdb.hrl

@@ -5,7 +5,7 @@
 -ifndef(EMQX_BRIDGE_IOTDB_HRL).
 -define(EMQX_BRIDGE_IOTDB_HRL, true).
 
--define(VSN_1_0_X, 'v1.0.x').
+-define(VSN_1_X, 'v1.x').
 -define(VSN_0_13_X, 'v0.13.x').
 
 -endif.

+ 3 - 3
apps/emqx_bridge_iotdb/src/emqx_bridge_iotdb.erl

@@ -109,10 +109,10 @@ basic_config() ->
             )},
         {iotdb_version,
             mk(
-                hoconsc:enum([?VSN_1_0_X, ?VSN_0_13_X]),
+                hoconsc:enum([?VSN_1_X, ?VSN_0_13_X]),
                 #{
                     desc => ?DESC("config_iotdb_version"),
-                    default => ?VSN_1_0_X
+                    default => ?VSN_1_X
                 }
             )}
     ] ++ resource_creation_opts() ++
@@ -217,7 +217,7 @@ conn_bridge_example(_Method, Type) ->
         is_aligned => false,
         device_id => <<"my_device">>,
         base_url => <<"http://iotdb.local:18080/">>,
-        iotdb_version => ?VSN_1_0_X,
+        iotdb_version => ?VSN_1_X,
         connect_timeout => <<"15s">>,
         pool_type => <<"random">>,
         pool_size => 8,

+ 4 - 4
apps/emqx_bridge_iotdb/src/emqx_bridge_iotdb_impl.erl

@@ -282,7 +282,7 @@ make_iotdb_insert_request(MessageUnparsedPayload, State) ->
     Message = MessageUnparsedPayload#{payload => PayloadParsed},
     IsAligned = maps:get(is_aligned, State, false),
     DeviceId = device_id(Message, State),
-    IotDBVsn = maps:get(iotdb_version, State, ?VSN_1_0_X),
+    IotDBVsn = maps:get(iotdb_version, State, ?VSN_1_X),
     Payload = make_list(maps:get(payload, Message)),
     PreProcessedData = preproc_data_list(Payload),
     DataList = proc_data(PreProcessedData, Message),
@@ -351,15 +351,15 @@ insert_value(1, Data, [Value | Values]) ->
 insert_value(Index, Data, [Value | Values]) ->
     [[null | Value] | insert_value(Index - 1, Data, Values)].
 
-iotdb_field_key(is_aligned, ?VSN_1_0_X) ->
+iotdb_field_key(is_aligned, ?VSN_1_X) ->
     <<"is_aligned">>;
 iotdb_field_key(is_aligned, ?VSN_0_13_X) ->
     <<"isAligned">>;
-iotdb_field_key(device_id, ?VSN_1_0_X) ->
+iotdb_field_key(device_id, ?VSN_1_X) ->
     <<"device">>;
 iotdb_field_key(device_id, ?VSN_0_13_X) ->
     <<"deviceId">>;
-iotdb_field_key(data_types, ?VSN_1_0_X) ->
+iotdb_field_key(data_types, ?VSN_1_X) ->
     <<"data_types">>;
 iotdb_field_key(data_types, ?VSN_0_13_X) ->
     <<"dataTypes">>.